To save to your PC, right mouse-click on the file name and select 'Save target As'.
PDF documents need the Acrobat(R) Reader from Adobe(R): Adobe, Acrobat and the Acrobat Logo are trademarks of Adobe Systems Incorporated. Free download from www.adobe.com
HygroPalm handheld instrument with interchangeable probe for the measurement of humidity and temperature featuring an integral 2000 point memory and USB interface.
The HP21 interfaces with the standard HC2-S probe for environmental measurements, and with the HK25/HK40 probes for measurement in ducts or high temperature applications.
Thanks to the digital interface between the HygroPalm handhelds and the HygroClip probes, the instrument can be easily applied to a wide variety of other applications such as paper, food, powders and granules.
Measurements can also be displayed on the backlit LCD in terms of dew/frost point, with other parameters and functions available, including the transfer of logged data, when connected to a PC running HW4 software.
Specification
Applications Food, pharmaceutical, printing and paper, laboratory, conservation, industry, science, and meteorology.
Probe type HygroClip® 2
Humidity sensor Probe dependent
Temperature sensor Probe dependent
Long term stability <1%rh / year
Number of probe inputs 1
Measuring range with interchangeable probe -50…200 °C
Calibration / adjustment Multipoint adjustment via keypad
Accuracy at 23 ±5 °C Depending on the probe and adjustment profile
Response time t 63 Probe dependent
Initialisation time Typically 2 sec
Measurement interval typically 1 second (without calculations)
Operating range electronics -10…60 °C
Allowed wind speed 20 m/sec
Display type Freely configurable graphic display
Backlight Yes
Battery indicator Low Batt. Display
Exploitation software ROTRONIC HW4
Menu guidance Yes
Trend indicator Yes
Statistical functions Min./ Max., Average
Probe adjustment by software With servicecable
Probe adjustment by keypad Single & multipoint %rh / °C
Psychrometric calculations Dew/frost point
Event logging System related events (FDA, GAMP compliant)
Firmware update Via Internet / HW4 Software
User information From HW4 Devicemanager
Data processing via HW4 Graphics, statistics, analysis, training, etc.
Device Protection by password Yes
Sensor diagnostics (drift, state)
Programmable. Factory setting: off
Audit Trail/ electronic records FDA 21 CFR Part 11 /GMP compatible
External datalogging 2000 records
Power supply / Power consumption 9 V battery, power supply
4 mA consumption without back light
Choice of Battery / rechargeable battery Yes
Communication interfaces ROTRONIC Interfacecable HW4 compatible
Service Interface UART
Service Information Calibration interval
Reverse voltage protection Mechanically in the plug
Max. cable length service cable 5 m
Max. probe cable length 10 m
Enclosure material ABS
Dimensions 268 x 72 x 30 mm
Weight approximately 210 g
IP protection rating IP40
Fire protection class Conforms UL94-HB
FDA/GAMP compatibility FDA CFR 21 Part 11 and GAMP
BSRIA Instrument Solutions reserve the right to change Instrument
specifications without notification. Hire Instrument Specifications may
differ from those claimed by the manufacturer.